{"id":41611,"date":"2022-04-28T09:47:24","date_gmt":"2022-04-28T09:47:24","guid":{"rendered":"https:\/\/armstronginternational.com\/emea\/industrias\/hpi-cpi\/mejores-practicas-en-la-instalacion-de-tuberias\/"},"modified":"2024-03-04T17:47:36","modified_gmt":"2024-03-04T17:47:36","slug":"mejores-practicas-en-la-instalacion-de-tuberias","status":"publish","type":"page","link":"https:\/\/armstronginternational.eu\/es\/industrias\/hpi-cpi\/mejores-practicas-en-la-instalacion-de-tuberias\/","title":{"rendered":"Mejores pr\u00e1cticas en la instalaci\u00f3n de tuber\u00edas"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"author":5,"featured_media":0,"parent":41607,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-41611","page","type-page","status-publish","hentry"],"acf":{"banner_type":"medium","video":"","banner_image":10000039813,"banner_heading":"Mejores pr\u00e1cticas en el dise\u00f1o e instalaci\u00f3n de tuber\u00edas de vapor y condensado para la industria de HPI\/CPI (Industria de procesos de hidrocarburos\/Industria de procesos qu\u00edmicos)","banner_subhead":"","banner_paragraph":"","button_link":"","button_label":"","modules":[{"module":"full","content_type_1":"narrow","padding":"pad-bottom","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"<h3>Las soluciones de Armstrong International est\u00e1n dise\u00f1adas a la medida para facilitar el mantenimiento, mejorar la fiabilidad y el desempe\u00f1o, y lograr actualizaciones y cambios m\u00e1s r\u00e1pidos.<\/h3>\r\nContacte a Armstrong para beneficiarse de las mejores pr\u00e1cticas en instalaci\u00f3n de tuber\u00edas por parte de expertos y dise\u00f1adas para satisfacer los requisitos espec\u00edficos de cada unidad, refiner\u00eda o de toda su empresa, en ubicaciones de todo el mundo. Como l\u00edderes mundiales en la optimizaci\u00f3n de sistemas de vapor y condensado, nuestros especialistas est\u00e1n preparados para ayudarle a resolver los problemas a los que se enfrenta su planta de refinaci\u00f3n de hidrocarburos o de procesamiento de sustancias qu\u00edmicas.\r\n<p align=\"center\"><a href=\"https:\/\/armstronginternational.eu\/es\/products\/?type=vapor-y-condensado&amp;industry=procesamiento-de-hidrocarburos-y-sustancias-quimicas&amp;regions=america\">Productos de vapor y condensado para la industria de HPI\/CPI (Industria de procesos de hidrocarburos\/Industria de procesos qu\u00edmicos)<\/a><\/p>\r\n<p align=\"center\"><a href=\"https:\/\/armstronginternational.eu\/es\/contacto\/\">Programe una evaluaci\u00f3n del sistema en su planta<\/a><\/p>","module_content_2":"","module_content_3":"","accordion":null,"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"full","content_type_1":"standard","padding":"pad-none","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"<h3 id=\"drainpoints\" style=\"text-align: center;\">Puntos de drenaje<\/h3>","module_content_2":"","module_content_3":"","accordion":null,"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"full","content_type_1":"accordion","padding":"pad-none","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"","module_content_2":"","module_content_3":"","accordion":[{"accordion_item_heading":"Steam Trap Location Points - Steam Main Header","accordion_item_body":"Instalar puntos de drenaje de condensado con trampas de vapor. Vapor saturado: cada 150 a 300\u00a0pies (25 a 50\u00a0m). Vapor sobrecalentado: cada 300 a 500\u00a0pies (50 a 75\u00a0m)\r\n\r\n<img class=\"alignnone wp-image-38774\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Steam-main-header-300x171.png\" alt=\"\" width=\"439\" height=\"250\" \/>"},{"accordion_item_heading":"Steam Valve Station Drainage","accordion_item_body":"Instalar trampas de vapor antes de las v\u00e1lvulas manuales que normalmente se encuentran cerradas, y antes de las v\u00e1lvulas reductoras de presi\u00f3n y v\u00e1lvulas de control.\r\n\r\n<img class=\"alignnone wp-image-38790\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Steam-Valve-Station-Drainage-300x242.png\" alt=\"\" width=\"372\" height=\"300\" \/> <img class=\"alignnone wp-image-38782\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Steam-Valve-Station-Drainage-2-300x115.png\" alt=\"\" width=\"521\" height=\"200\" \/>"},{"accordion_item_heading":"Steam Trap Location Points - Steam Main Header","accordion_item_body":"Instalar puntos de drenaje de condensado con trampas de vapor en la parte inferior de cualquier elevaci\u00f3n vertical, independientemente de la direcci\u00f3n del flujo de vapor.\r\n\r\n<img class=\"alignnone wp-image-38766\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Steam-Main-Header-2-268x300.png\" alt=\"\" width=\"357\" height=\"400\" \/>"},{"accordion_item_heading":"Steam Trap Location Points \u2013 End of Steam Main \/ Header \/ Line ","accordion_item_body":"La instalaci\u00f3n de eliminadores de aire al final de la ubicaci\u00f3n principal evitar\u00e1 que el aire quede atrapado en el cabezal de vapor, especialmente durante los per\u00edodos de puesta en marcha.\r\n\r\n<img class=\"alignnone wp-image-38758\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/End-of-steam-main-header-300x218.png\" alt=\"\" width=\"413\" height=\"300\" \/> <img class=\"alignnone wp-image-38750\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/End-of-steam-main-header-2-300x107.jpg\" alt=\"\" width=\"562\" height=\"200\" \/>"}],"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"full","content_type_1":"standard","padding":"pad-none","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"<h3 id=\"drippockets\" style=\"text-align: center;\">Dep\u00f3sitos colectores de goteo<\/h3>","module_content_2":"","module_content_3":"","accordion":null,"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"full","content_type_1":"accordion","padding":"pad-none","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"","module_content_2":"","module_content_3":"","accordion":[{"accordion_item_heading":"Steam Main Header Drip Trap \u2013 Saturated (\u2264 650 psig \/45 barg) ","accordion_item_body":"<img class=\"alignnone wp-image-38801\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image017-300x187.png\" alt=\"\" width=\"481\" height=\"300\" \/>"},{"accordion_item_heading":"Steam Main Header Drip Trap \u2013 Saturated (\u2264 650 psig \/45 barg)","accordion_item_body":"<img class=\"alignnone wp-image-38817\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image018-300x195.png\" alt=\"\" width=\"385\" height=\"250\" \/> <img class=\"alignnone wp-image-38809\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image018-2-drip-pocket-chart1_0-300x218.jpg\" alt=\"\" width=\"275\" height=\"200\" \/>"},{"accordion_item_heading":"Steam Main Header Drip Trap \u2013 Saturated (\u2264 650 psig \/45 barg)","accordion_item_body":"<img class=\"alignnone size-medium wp-image-38825\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image020-300x160.png\" alt=\"\" width=\"300\" height=\"160\" \/>"},{"accordion_item_heading":"Steam Main Header Drip Trap \u2013 Superheated (\u2264 650 psig &amp; 600\u00b0F \/ 45 barg &amp; 315\u00b0C) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-38833\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image021-300x194.png\" alt=\"\" width=\"300\" height=\"194\" \/> <img class=\"alignnone size-medium wp-image-38841\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image022-300x261.png\" alt=\"\" width=\"300\" height=\"261\" \/>"},{"accordion_item_heading":"Steam Main Header Drip Trap \u2013 Superheated (\u2264 650 psig &amp; 600\u00b0F \/ 45 barg &amp; 315\u00b0C) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-38849\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image023-300x197.png\" alt=\"\" width=\"300\" height=\"197\" \/>"},{"accordion_item_heading":"Steam Main Header Drip Trap \u2013 Superheated (\u2264 650 psig &amp; 600\u00b0F \/ 45 barg &amp; 315\u00b0C) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-38857\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image024-300x186.png\" alt=\"\" width=\"300\" height=\"186\" \/> <img class=\"alignnone size-medium wp-image-38865\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image025-300x259.png\" alt=\"\" width=\"300\" height=\"259\" \/>"},{"accordion_item_heading":"Steam Main Header Drip Trap \u2013 Saturated (650 \u2264 1,800 psig \/ 45 \u2264 124 barg ) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-38873\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image026-300x181.png\" alt=\"\" width=\"300\" height=\"181\" \/>"},{"accordion_item_heading":"Steam Main Header Drip Trap - Superheated Single Block and Bleed (650 \u2264 1,245 psig @ 900\u00b0F \/ 45 \u2264 86 barg @ 482\u00b0C) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-38881\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image027_1-300x166.png\" alt=\"\" width=\"300\" height=\"166\" \/><img class=\"alignnone size-medium wp-image-38897\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image028_0-300x261.png\" alt=\"\" width=\"300\" height=\"261\" \/>"},{"accordion_item_heading":"Steam Main Header Drip Trap \u2013 Double Block and Bleed (650 \u2264 1,245 psig @ 900 \u00b0F \/ 45 \u2264 86 barg @ 482\u00b0C) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-38889\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image027-2-300x166.png\" alt=\"\" width=\"300\" height=\"166\" \/> <img class=\"alignnone size-medium wp-image-38905\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image028-300x261.png\" alt=\"\" width=\"300\" height=\"261\" \/>"},{"accordion_item_heading":"Steam Main Header Drip Trap \u2013 Superheated, Double Block and Bleed (650 \u2264 1,245 psig @ 900 \u00b0F\/45 \u2264 86 barg @ 482\u00b0C) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-38913\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image029-300x156.png\" alt=\"\" width=\"300\" height=\"156\" \/>"},{"accordion_item_heading":"Steam Main Header Drip Trap \u2013 Superheated, Double Block and Bleed (650 \u2264 1,245 psig @ 900 \u00b0F \/ 45 \u2264 86 barg @ 482\u00b0C) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-38921\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image030-300x173.png\" alt=\"\" width=\"300\" height=\"173\" \/> <img class=\"alignnone size-medium wp-image-38929\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image031-300x260.png\" alt=\"\" width=\"300\" height=\"260\" \/>"}],"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"full","content_type_1":"standard","padding":"pad-none","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"<h3 id=\"processheaters\" style=\"text-align: center;\">Calentadores de proceso<\/h3>","module_content_2":"","module_content_3":"","accordion":null,"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"full","content_type_1":"accordion","padding":"pad-none","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"","module_content_2":"","module_content_3":"","accordion":[{"accordion_item_heading":"Shell &amp; Tube Heat Exchanger \u2013 Horizontal \u2013 Saturated Steam on Shell Side (\u2264 650 psig \/45 barg)\u2028 Constant Positive Differential Pressure (Non-Stall) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-38939\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image032-300x192.png\" alt=\"\" width=\"300\" height=\"192\" \/>"},{"accordion_item_heading":"Shell &amp; Tube Heat Exchanger \u2013 Horizontal \u2013 Saturated Steam on Shell Side (\u2264 200 psig \/14 barg)\u2028 Modulating Differential Pressure (Stall) \u2013 Closed System ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-38947\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image033-300x172.png\" alt=\"\" width=\"300\" height=\"172\" \/>"},{"accordion_item_heading":"Shell &amp; Tube Heat Exchanger \u2013 Horizontal \u2013 Saturated Steam on Tube Side (\u2264 650 psig \/45 barg) \u2028Constant Positive Differential Pressure (Non-Stall)","accordion_item_body":"<img class=\"alignnone size-medium wp-image-38955\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image034-300x179.png\" alt=\"\" width=\"300\" height=\"179\" \/>"},{"accordion_item_heading":"Shell &amp; Tube Heat Exchanger \u2013 Horizontal \u2013 Saturated Steam on Tube Side (\u2264 200 psig \/ 14 barg) \u2028Modulating Differential Pressure (Stall) \u2013 Closed System","accordion_item_body":"<img class=\"alignnone size-medium wp-image-38963\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image035-300x207.png\" alt=\"\" width=\"300\" height=\"207\" \/>"},{"accordion_item_heading":"Shell &amp; Tube Heat Exchanger \u2013 Vertical \u2013 Saturated Steam on Tube Side (\u2264 650 psig \/ 45 barg) \u2028Constant Positive Differential Pressure (Non-Stall) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-38971\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image036-300x187.png\" alt=\"\" width=\"300\" height=\"187\" \/>"},{"accordion_item_heading":"Shell &amp; Tube Heat Exchanger \u2013 Vertical \u2013 Saturated Steam on Shell Side (\u2264 200 psig \/14 barg)\u2028 Modulating Differential Pressure (Stall) \u2013 Closed System","accordion_item_body":"<img class=\"alignnone size-medium wp-image-38979\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image037-300x165.png\" alt=\"\" width=\"300\" height=\"165\" \/>"},{"accordion_item_heading":"Shell &amp; Tube Heat Exchanger \u2013 Vertical \u2013 Saturated Steam on Tube Side (\u2264 650 psig \/ 45 barg) \u2028Constant Positive Differential Pressure (Non-Stall) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-38987\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image038-300x172.png\" alt=\"\" width=\"300\" height=\"172\" \/>"},{"accordion_item_heading":"Shell &amp; Tube Heat Exchanger \u2013 Vertical \u2013 Saturated Steam on Tube Side (\u2264 200 psig \/ 14 barg) \u2028Modulating Differential Pressure (Stall) \u2013 Closed System ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-38995\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image039-300x169.png\" alt=\"\" width=\"300\" height=\"169\" \/>"}],"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"full","content_type_1":"standard","padding":"pad-none","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"<h3 id=\"opensystems\" style=\"text-align: center;\">Sistemas abiertos<\/h3>","module_content_2":"","module_content_3":"","accordion":null,"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"full","content_type_1":"accordion","padding":"pad-none","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"","module_content_2":"","module_content_3":"","accordion":[{"accordion_item_heading":"Condensate from Multiple Sources \u2013 Saturated (\u2264 150 psig \/ 10 barg) Negative Differential Pressure \u2013 Open System ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-39003\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image040-300x155.png\" alt=\"\" width=\"300\" height=\"155\" \/>"},{"accordion_item_heading":"Condensing Steam Turbine \u2013 Saturated (\u2264 150 psig \/ 10 barg) Negative Differential Pressure \u2013 Closed System ","accordion_item_body":"<img class=\"size-medium wp-image-39011\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/image041-300x191.png\" alt=\"\" width=\"300\" height=\"191\" \/>"}],"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"full","content_type_1":"standard","padding":"pad-none","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"<h3 id=\"turbines\" style=\"text-align: center;\">Turbinas<\/h3>","module_content_2":"","module_content_3":"","accordion":null,"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"full","content_type_1":"accordion","padding":"pad-none","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"","module_content_2":"","module_content_3":"","accordion":[{"accordion_item_heading":"Steam Turbine Saturated \u2013 Single Stage Positive Differential Pressure (\u2264 650 Psig\/ 45 Bar Saturated) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-39027\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Turbines-1-300x130.png\" alt=\"\" width=\"300\" height=\"130\" \/>"},{"accordion_item_heading":"Steam Turbine Saturated \u2013 Multiple Stages Positive Differential Pressure (\u2264 650 Psig\/ 45 Bar Saturated) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-39035\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Turbines-2-300x113.jpeg\" alt=\"\" width=\"300\" height=\"113\" \/>"},{"accordion_item_heading":"Steam Turbine \u2013 Single Stage Positive Differential Pressure Low Pressure (\u2264 450 Psig\/ 31 Bar Superheated) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-39043\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Turbines-3-300x124.jpeg\" alt=\"\" width=\"300\" height=\"124\" \/>"},{"accordion_item_heading":"Steam Turbine \u2013 Single Stage Positive Differential Pressure High Pressure (\u2264 1245 Psig\/ 86 Bar Superheated) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-39051\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Turbines-4-300x114.jpeg\" alt=\"\" width=\"300\" height=\"114\" \/>"},{"accordion_item_heading":"Steam Turbine Superheated \u2013 Multiple Stages Positive Differential Pressure Low Pressure (\u2264 450 Psig\/ 31 Bar Superheated) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-39019\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Turbines-5-300x102.jpeg\" alt=\"\" width=\"300\" height=\"102\" \/>"},{"accordion_item_heading":"Steam Turbine \u2013 Multiple Stages Positive High Pressure (450 Psig \u2264 1245 Psig\/ 31 Bar \u2264 86 Bar Superheated) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-39059\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Turbines-6-300x121.jpeg\" alt=\"\" width=\"300\" height=\"121\" \/>"}],"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"full","content_type_1":"standard","padding":"pad-none","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"<h3 id=\"flares\" style=\"text-align: center;\">Combustiones<\/h3>","module_content_2":"","module_content_3":"","accordion":null,"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"full","content_type_1":"accordion","padding":"pad-none","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"","module_content_2":"","module_content_3":"","accordion":[{"accordion_item_heading":"Flare Systems \u2013 Single Steam Supply (\u2264 200 psig \/ 14 barg) Closed System ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-39068\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Flares-1-300x233.png\" alt=\"\" width=\"300\" height=\"233\" \/>"},{"accordion_item_heading":"Flare Systems \u2013 Multiple Steam Supplies (\u2264 150 psig \/ 10 barg) Open System ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-39076\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Flares-2-300x188.png\" alt=\"\" width=\"300\" height=\"188\" \/>"}],"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"full","content_type_1":"standard","padding":"pad-none","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"<h3 id=\"storagetanks\" style=\"text-align: center;\">Tanques de almacenamiento<\/h3>","module_content_2":"","module_content_3":"","accordion":null,"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"full","content_type_1":"accordion","padding":"pad-none","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"","module_content_2":"","module_content_3":"","accordion":[{"accordion_item_heading":"Storage Tank Coil Types","accordion_item_body":"<img class=\"alignnone size-medium wp-image-39084\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Storage-Tanks-1-300x179.jpeg\" alt=\"\" width=\"300\" height=\"179\" \/>"},{"accordion_item_heading":"Storage Tank \u2013 Saturated \u2013 Single Steam Supply Constant Pressure (Non-Stall) (0 \u2264 650 psig \/ 0 \u2264 45 barg) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-39092\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Storage-Tanks-2-300x175.png\" alt=\"\" width=\"300\" height=\"175\" \/>"},{"accordion_item_heading":"Storage Tank \u2013 Saturated \u2013 Single Steam Supply Modulating Pressure (Stall) (0 \u2264 200 psig \/ 0 \u2264 14 barg) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-39100\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Storage-Tanks-3-300x212.png\" alt=\"\" width=\"300\" height=\"212\" \/>"},{"accordion_item_heading":"Multiple Storage Tanks \u2013 Saturated \u2013 Single Steam Supply Constant Pressure (\u2264 150 psig \/10 barg) ","accordion_item_body":"<img class=\"alignnone size-medium wp-image-39108\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Storage-Tanks-4-300x164.png\" alt=\"\" width=\"300\" height=\"164\" \/>"}],"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"full","content_type_1":"standard","padding":"pad-none","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"<h3 id=\"tracing\" style=\"text-align: center;\">Rastreo<\/h3>","module_content_2":"","module_content_3":"","accordion":null,"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"full","content_type_1":"accordion","padding":"pad-bottom","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"","module_content_2":"","module_content_3":"","accordion":[{"accordion_item_heading":"Steam Tracing Systems","accordion_item_body":"<img class=\"alignnone size-medium wp-image-39116\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Tracing-1-300x143.jpeg\" alt=\"\" width=\"300\" height=\"143\" \/> <img class=\"alignnone size-medium wp-image-39124\" src=\"https:\/\/armstronginternational.eu\/wp-content\/uploads\/Tracing-2-300x143.jpeg\" alt=\"\" width=\"300\" height=\"143\" \/>"}],"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"submenu","content_type_1":"standard","padding":"pad-none","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"<section class=\"full-width pad-none \">\r\n<div class=\"container\">\r\n<h2 align=\"center\">Descubra lo que la experiencia global de Armstrong en la industria de HPI\/CPI (Industria de procesos de hidrocarburos\/Industria de procesos qu\u00edmicos) puede hacer por usted<\/h2>\r\n<\/div>\r\n<\/section>","module_content_2":"","module_content_3":"","accordion":null,"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":[{"link":{"type":"post","value":"4946","title":"","target":false},"label":"P\u00e1gina de inicio de HPI\/CPI\u00a0"},{"link":{"type":"url","value":"https:\/\/armstronginternational.eu\/industries\/hpi-cpi\/safety-liability\/","title":"","target":false},"label":"Seguridad & Responsabilidad\u00a0"},{"link":{"type":"url","value":"https:\/\/armstronginternational.eu\/industries\/hpi-cpi\/productivity\/","title":"","target":false},"label":"Productividad & ahorro"},{"link":{"type":"url","value":"https:\/\/armstronginternational.eu\/industries\/hpi-cpi\/trap-selection\/","title":"","target":false},"label":"Gu\u00edas de selecci\u00f3n de trampas de vapor"},{"link":{"type":"url","value":"https:\/\/armstronginternational.eu\/industries\/hpi-cpi\/piping\/","title":"","target":false},"label":"Mejores pr\u00e1cticas en la instalaci\u00f3n de tuber\u00edas"},{"link":{"type":"url","value":"https:\/\/armstronginternational.eu\/es\/products\/?industry=procesamiento-de-hidrocarburos-y-sustancias-quimicas&regions=america","title":"","target":false},"label":"Productos & Sistemas"}]}]},"_links":{"self":[{"href":"https:\/\/armstronginternational.eu\/es\/wp-json\/wp\/v2\/pages\/41611","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/armstronginternational.eu\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/armstronginternational.eu\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/armstronginternational.eu\/es\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/armstronginternational.eu\/es\/wp-json\/wp\/v2\/comments?post=41611"}],"version-history":[{"count":0,"href":"https:\/\/armstronginternational.eu\/es\/wp-json\/wp\/v2\/pages\/41611\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/armstronginternational.eu\/es\/wp-json\/wp\/v2\/pages\/41607"}],"wp:attachment":[{"href":"https:\/\/armstronginternational.eu\/es\/wp-json\/wp\/v2\/media?parent=41611"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}